440 A 12/24/48 V Wind/Solar Battery Charge Controller
440 A 12/24/48 V Wind/Solar Battery Charge Controller
Perfect for wind/hydro battery based systems.
440 Amp - Diversion (Charge)
Regulator
With Two High contrast Meters (both Volts and Amps)
Two D/C breakers/disconnects.
Fully wired, ready to go for both wind and solar.
Works directly with 12, 24 and 48 volt systems
This diversion controller is the result of our many attempts to use the controllers currently on the market (offered by some of the largest names in the business), to work in conjunction with our wind turbines. None of the other diversion controllers on the market did what we needed a diversion controller to do. So we designed our own and added all of the features that are truly needed in a diversion controller.
Built around a solenoid that we have tested (tortured) in-house at over 460 amps, this controller is user adjustable, has a large enclosure, microprocessor controlled, test button and battery status indications
Use this controller to regulate and prevent battery overcharge in:
Some of the key features of this controller are:
Some specifics about the points made above.
The microprocessor is the heart of the controller. It is given the battery voltage and the user changeable trip points. This information is analyzed and acted upon.
The Battery level is checked, and based on that info, the Green LED flashes or is illuminated as follows
- (One) Flash indicates the battery is less than 12 volts (12 volt system - Double for 24 etc)
- (Two) Flashes indicates the battery is 12 to 12.5V
- (Three) Flashes indicates the battery is 12.6 to 13v
- (Four) Flashes indicate the battery is 13.1 to 13.5V
- ( Five) Flashes indicates the battery is above 13.5V but less than 13.9V (Settings are adjustable)
Steady green means the battery is full.
The red LED is illuminated when the battery is being dumped at 14.5v (or the charge source diverted.)
The dump remains active for a minimum of 5 seconds, at which time it is checked by the microprocessor. If battery voltage drops below the "Dump Cancel " level, the dump is disabled, otherwise the dump is continued and rechecked every 5 seconds.
When you click the "TEST" push-button - the 5 second cycle is started (one time, unless the batteries are within the "Dump Start" and "Dump Cancel" zone.)
Settings are user changeable! By simply turning a simple potentiometer with a small screwdriver, you can quickly adjust the trip point.
The enclosure is heavy gauge, solid steel, ready to mount. -- No plastic, no junk, simple and rugged.
This Hoffman pull box is perfect for terminating larger wire. It has multiple knockouts on each side of the box. The box measures 8.25" x 12". The electronics are fully isolated from the box.
Use this controller to regulate and prevent battery overcharge in:
Some of the key features of this controller are:
Some specifics about the points made above.
The microprocessor is the heart of the controller. It is given the battery voltage and the user changeable trip points. This information is analyzed and acted upon.
The Battery level is checked, and based on that info, the Green LED flashes or is illuminated as follows
- (One) Flash indicates the battery is less than 12 volts (12 volt system - Double for 24 etc)
- (Two) Flashes indicates the battery is 12 to 12.5V
- (Three) Flashes indicates the battery is 12.6 to 13v
- (Four) Flashes indicate the battery is 13.1 to 13.5V
- ( Five) Flashes indicates the battery is above 13.5V but less than 13.9V (Settings are adjustable)
Steady green means the battery is full.
The red LED is illuminated when the battery is being dumped at 14.5v (or the charge source diverted.)
The dump remains active for a minimum of 5 seconds, at which time it is checked by the microprocessor. If battery voltage drops below the "Dump Cancel " level, the dump is disabled, otherwise the dump is continued and rechecked every 5 seconds.
When you click the "TEST" push-button - the 5 second cycle is started (one time, unless the batteries are within the "Dump Start" and "Dump Cancel" zone.)
Settings are user changeable! By simply turning a simple potentiometer with a small screwdriver, you can quickly adjust the trip point.
The enclosure is heavy gauge, solid steel, ready to mount. -- No plastic, no junk, simple and rugged.
This Hoffman pull box is perfect for terminating larger wire. It has multiple knockouts on each side of the box. The box measures 8.25" x 12". The electronics are fully isolated from the box.

About load diversion.
Several schools of thought on the subject.
We happen to believe that is far better to leave the wind turbine connected to the batteries at all times. Why? When you remove the battery level voltage from a wind turbine and send its power directly to a load, then it sees for all practical purposes a short circuit (depending on the resistance of the load and lead wires.) This may cause the turbine blades to slow dramatically and in some cases bring it to a halt. This braking action can cause heat build up in the stator if it is repeated every few seconds or so (if the battery is just a little over the top). When you allow the turbine to see the batteries, along with the load, the turbine remains more within its design realm -- always a good thing.
The internal relay is configured to dump the batteries along with the source, but if you desire to disconnect the source from the batteries and send it to the load directly, simply utilize the N/C contacts of the relay as well. We'll be happy to send you a diagram -- this is a very simple to accomplish.
- Can they handle 48 volt systems directly?
Do they have battery status indication?- Do they show you the the current flow from your turbine?
- Do they have multiple, pre-installed, pre-wired circuit breakers?
- Do the meters have an on/off switch?
Do they have a dump active indication? Are the dump levels user changeable? Are they microprocessor controlled? Do they come with a enclosure that's actually ready to use? Do they handle the amperage you need? Do they have a dump test capability?- Are they reverse polarity protected?
When you compare this controller to the others, you will see why we built it and why we know you'll love it.

** 150 amp heat activated breakers have been installed to limit continuous current to 150 amps. Instantaneous current handling of this unit not to exceed 440 amps. **